Skip to end of metadata
Go to start of metadata

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 2 Current »

The pinout for the serial console cable (J2) to DB25 is as follows. Take the following image as an indication of the numbering scheme on the 20 pin connector:

We’re looking at the FRONT and number from left to right.

We have the following connections:

Pin

To DB25

Pin

To DB25

1

NC

11

NC

2

CLOSED HOLE

12

NC

3

NC

13

NC

4

pin 3

14

NC

5

pin 2

15

NC

6

NC

16

NC

7

NC

17

NC

8

PIN 20

18

NC

9

GND

19

NC

10

NC

20

NC

A cable can be made easily by taking a bit of ribbon cable and a ribbon connector.

My cable uses a DB9 connector that removes the need for a cross cable:

Pin 4: (green wire) to pin 2 of a DB9
Pin 5: (yellow) to pin 3
Pin 8 (brown) to pin
Pin 9 (mantle) to pin 5

WATCH OUT: The original connector LOOKS like a 24 pin connector, but the FIRST and LAST columns are empty, and the receiving connector has no pins there!!