9825A Error codes

Copy from the error codes booklet

*: these errors give a cursor in the line when the RECALL button is pressed, indicating the location of the error in the line.

Code

Desc

Code

Desc

00

System Error

01

Unexpected peripheral interrupt

02*

Unterminated text

03*

Mnemonic is unknown

04

System is secured

05

Operation not allowed; line cannot be stored; executed with line number

06*

Syntax error in number

07*

Syntax error in input line

08

Internal representation of the line is too long (gives cursor sometimes)

09

Gto, gsb, or end statement not allowed in present context (1: see also Advanced Programming ROM error messages)

10*

Gto or gsb statement requires an integer

11

Integer out of range or integer required. Must be between -32768 and 32767

12*

Line cannot be stored; can only be executed

13

Enter (ent) statement not allowed in current context

14

Program structure destroyed

15

Printer out of paper or printer failure

16

String variables ROM not present for the string comparison. Argument in relational comparison operator not allowed.

17

Parameter out of range

18

Incorrect parameter

19

Bad line number

20

Missing ROM or binary program. The second number indicates the missing ROM. In the program mode, the line number is given instead of the ROM number.

1: Binary Program
4: Systems Programming
6: Strings
8: Extended I/O
9: Advanced programming
10: Matrix
11: Plotter (9862A or 9872A)
12: General I/O
15: 9885 Disk

21

Line is too long to store

22

Improper dimension specification

23

Simple variable already allocated

24

Array already dimensioned

25

Dimensions of array disagree with number of subscripts

26

Subscript of array element out of bounds

27

Undefined Array

28

Ref statement has no matching gsb statement

29

Cannot execute line because a ROM or binary program is missing

30

Special function key not defined

31

Non-existent program line

32

Improper data type (1: see also Advanced Programming ROM error messages)

33

Data types do not match in assignment statement

34

Display overflow due to pressing a special function key

35

Improper flag reference (no such flag)

36

Attempt to delete destination of a gto or gsb statement

37

Display buffer overflow caused by display (dsp) statement

38

Insufficient memory for subroutine return pointer (1)

39

Insufficient memory for variable allocation or binary program

40

Insufficient memory for operation

41

No cartridge in tape transport

42

Tape cartridge is write protected

43

Unexpected Beginning-of-tape (BOT) or End-of-tape (EOT) marker encountered, or a tape transport failure

44

Verify has failed

45

Attempted execution of idf statement without parameters, or mkr statement when tape position is unknown

46

Read error of file body (See appendix F)

47

Read error of file head (see appendix F)

48

End-of-tape (EOT) encountered before specified number of files were marked

49

File too small

50

Ldf statement for a program file must be the last statement in the line

51

A ROM is present but was not when the memory was recorded. Remove the ROM indicated by the number to the right of the error number in the display, and re-execute the ldm statement. In the program mode, the line number is given instead of the ROM number. See error 20 for a list of ROM numbers.

 

Â